This post is about how piezoelectric transducer work. Piezoelectric transducer is used to measure force, pressure and acceleration. These sensors contain a piezoelectric element that generates the electric charge in response to some mechanical stress.

So if we apply a displacement mechanical force, characterised by displacement x to the piezoelectric crystal, it generates an electric charge q, in accordance to the statement q=Kx.

Figure 1 shows the simple scheme of the piezoelectric transducer. The piezoelectric transducer can also be represented by the circuit model in Figure 2, consisting of the current source and parallel capacitor – representing the charge generated by the piezoelectric element, after an application of an external force, and the physical structure of a piezoelement.

Figure 1. Piezoelectric sensor
Figure 1. Piezoelectric sensor
Figure 2. Equivalent circuit piezoelectric sensor
Figure 2. Equivalent circuit piezoelectric sensor
vout=1Cidt=qC=KxC The output voltage of the piezoelectric transducer can be increased by an amplifier, and it is very convenient to use a charge amplifier in this case, due to very high input impedance. High impedance makes  input current of the amplifier negligible. High gain of the amplifier makes the total voltage across the amplifier zero. So in accordance with Kirchhoff’s Law for currents, the feedback current is equal to the transducer current with the opposite sign if(t)=i, so

vout(t)=1Cf if(t)dt=qCf=KxCf

As the displacement x is made by the external force, that is why this device is used regularly for force and pressure measurement.

Figure 3. A piezoelectric transducer with a change amplifier circuit
Figure 3. A piezoelectric transducer with a change amplifier circuit

Figure 4 depicts a piezoelectric sensor, converting forces directly into a 0V to 10V signal by manufacturer HBM. This sensor consists of the pre-stressed and calibrated sensor, a three metre long charging cable and a charge amplifier. This sensor has a very broad measurement range with a capacity of 5–120kN. This sensor has two measurement regimes, 20% and 100% calibrated. It’s resistive to electromagnetic interference.

Figure 4.The piezoelectric transducer of manufacturer HBM
Figure 4.The piezoelectric transducer of manufacturer HBM

More educational tutorials can be accessed via Reddit community r/ElectronicsEasy.

Digital position encoder

Tags:

Leave a Reply